Send Message
Guangzhou YIGU Medical Equipment Service Co.,Ltd

Power Supply Board HeartStart MRX For IntelliVue MX450 Patient Monitor PN 509-100247-0001

Product Details:
Brand Name: HeartStart MRX
Model Number: MX450
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiate
Packaging Details: Box
Delivery Time: Within two days
Payment Terms: T/T, Western Union, PayPal
Supply Ability: 20
  • Detail Information
  • Product Description

Detail Information

Brand: HeartStart MRX Model: MX450
Application: Patient Monitor Warranty: 90 Days
Shipping: All Over The World Condition: Original
Material: Plastic Quality: Excellent
Highlight:

509-100247-0001 Patient Monitor Power Supply

,

IntelliVue MX450 Patient Monitor Power Supply

,

HeartStart MRX Patient Monitor Power Supply

Product Description

The following is a breakdown of the features of the HeartStart MRX IntelliVue MX450 power supply board:

1. Reliable Power supply: The MX450 power supply board provides a reliable power supply to ensure the normal operation and stable performance of the equipment.

2. Multiple power options: The power board supports a variety of power options, including AC and DC, to adapt to different power environments and usage scenarios.

3. Battery backup: The power supply board has the battery backup function. When the main power supply is interrupted, it can automatically switch to the battery power supply to ensure the continuous operation of the device and the monitoring function.

4. Battery charging management: The power board is equipped with a battery charging management system, which can charge and manage the battery to ensure its charging status and life.

5. Overcurrent and overheat protection: The power module has an overcurrent and overheat protection mechanism. When the current exceeds the safe range or the temperature is too high, the power module automatically powers off or takes protective measures to ensure the safety of the device and users.

6. Replaceable and repairable: The power board is designed as a replaceable and repairable component, and if it fails or is damaged, the power board can be replaced without having to replace the entire device, saving maintenance costs and time.

7. Energy efficiency optimization: The power board is designed with energy efficiency optimization to reduce energy consumption and heat generation and improve the operating efficiency and stability of the equipment.

Please note that the above description is based on a general understanding of the HeartStart MRX IntelliVue MX450 power supply board, and specific features may vary by product version and configuration.

 

For the HeartStart MRX IntelliVue MX450 power supply board repair and replacement process, the following are the general steps:

1. Safety preparation: Before performing any repair or replacement operations, ensure that the device is disconnected and in a safe state. Follow medical device safety procedures and manufacturer's safety recommendations.

2. Get the right power board: Contact your device manufacturer or supplier to get the right power board for the MX450. Ensure that the power supply board matches the device model and configuration.

3. Tools: Prepare necessary tools, such as screwdrivers and wrenches, to open the cover of the device and screws to secure the power module.

4. Disconnect: Disconnect the device from the power board before operating it. This may involve removing the cable connector or plug.

5. Remove the old power strip: Using the appropriate tools, unfasten the screws or clamps holding the power strip in place. Carefully remove the old power strip from the inside of the device.

6. Install the new power supply board: Place the new power supply board in the correct position and ensure that it is aligned with the interface of the device. Use the appropriate tools, secure the power supply board, and follow the manufacturer's instructions for proper installation.

7. Connect the cable: Reconnect the previously disconnected cable connector or plug to the appropriate interface on the new power strip. Make sure the connection is secure.

8. Close the device cover: Reinstall and secure the device cover. Make sure the housing is completely closed and secured to protect the internal circuitry and components.

9. Test and verification: Reconnect the power supply to the device and perform the necessary tests and verification to ensure that the newly installed power supply board is working properly. Check whether the power supply and functions of the device are normal.

Please note that the above steps are general guidelines and may vary depending on the device model, manufacturer requirements, or service procedures.

 

After replacing the HeartStart MRX IntelliVue MX450 power board, here are some test and verification actions to ensure that the new power board is working properly:

1. Power supply test: Connect the device power supply to ensure that the new power supply board can provide power supply normally. Verify that the device is up and running and that there is sufficient power to support the functions of the device.

2. Functional test: Test the functions of the MX450, including monitoring function, waveform display, alarm and communication function. Ensure that the new power supply board does not affect the normal operation and function of the device.

3. Battery charge test: If the power board involves battery charge management, conduct a battery charge test to ensure that the new power board can properly charge and manage the battery. Verify battery charging status and battery life.

4. Connector and interface test: Check the connectors and interfaces on the new power supply board to ensure that they are properly connected to the rest of the device and are not loose or in poor contact. Perform the necessary connection tests to ensure the proper operation of data transmission and communication.

5. Safety and stability testing: Test the safety performance and stability of the equipment to ensure that the new power supply board does not introduce any potential safety risks or performance issues. Verify the stability of the equipment under different operating modes and load conditions.

6. Firmware and software validation: If replacing the power board involves firmware or software updates, perform the corresponding firmware and software validation to ensure that the firmware and software of the device are compatible with the new power board and that there are no errors or mismatches.

Please note that the above testing and verification operations are general guidelines, and specific testing procedures and requirements may vary depending on the device model, manufacturer requirements, or service procedures.

Power Supply Board HeartStart MRX For IntelliVue MX450 Patient Monitor PN 509-100247-0001 0

Get in touch with us

Enter Your Message

You Might Be Into These