Product Description
New condition LCD PN R150XJE-L01 Patient Monitoring Display
Brand Name:
Name: LCD Patient Monitoring Display
PN: R150XJE-L01
we are also selling power supply, printer, high voltage board, blood oxygen board, ECG board, keypress board, mainboard, NIBP board (pump) of mindray PM series monitor. Do let us know your kind enquiry. Do not hesitate to contact with us for futher information.
Company Business Scope
- A. ECG monitor, Fetal monitor, Defibrillator, Electrocardiograph, Oximeter for repairing and accessories for selling.
- B. Mainboard, Power Stripe/Panel, Touch Screen, Viewing screen, Button Board, ECG/Oximeter/Blood Press Module for repairing and selling.
- C. Medical Patient Monitor/Electrocardiograph for leasing, maintenance, guarantee repair and exchange.
Common Faults Repair
- 1. Unbootable/ Unable to boot up 2. The module ( M3001A ) can’t detect blood pressure.
- 3. The module can’t be connected. 4. Automatically disconnect.
- 5. The sphygmomanometer has a leak. 6. NIBP equipment failure.
- 7. Unable to contact. 8. Error reporting MMS disconnected.
- 9. False alarm MMS pull out. 10. Can’t load out.
- 11. ECG malfunctions. 12. ECG equipment out of order.
- 13. Software upgrades. 14. NIBP fails to inflate.
- 15. IBP equipment faults. 16. M3012A module can’t be detected.
- 17. Automatically restart. 18. The encoder can’t work.
- 19. Blue screen appears after startup. 20. No ECG signal.
- 21. Unable to enter the select menu. 22. Alarm occurs when starting up, and the failure light is on.
- 23. Report CO2 plugging. 24. MMSL developing module faults.
- 25. M3015A / M3001A module faults. 26. No power display light.
- 27. NBP equipment faults. 28. ECG and oximeter equipment faults.
- 29. LCD lamp aging. 30. Inflated blood pressure does not indicate a number.
- 31. The key plate is out of order. 32. Encoder failure.
- 33. Can’t inflate. 34. NIBP equipment faults.
- 35. SP O2 and ECG equipment fault. 36. Unable to charge.
- 37. The touch screen can’t work. 38. The screen shows double image.
- 39. Error code 1000. Error code 20004. 40. No alarm sounds.
Business Scopes |
Repairing Services |
Monitor, ECG, Defibrillator, Oximeter, Electrocardiograph, Fetal monitor and spare parts |
Sell and Replace |
Mainboard, Circuit board, Power strip/ panel, Battery, SP O2 and ECG module, Parameter module, Display screen, Touch screen, Encoder, Keyboard plate, Sensor, Probe, Cable etc. |
Service Brands |
GE, , SPACELABS, SIEMENS, MINDRAY, NIHON KOHDEN, , TYCO, NONIN, TOSHIBA, MEDISON, BIOSOUND, HITACHI, HP, ATL, ALOKA etc. |
1. Maintenance Services:
ECG monitor, Defibrillator, Oximeter, Electrocardiograph, Fetal monitor
2. Sell and Replace:
Mainboard, Circuit board, Power strip/ panel, Battery, SP O2 and ECG module, Parameter module, Display screen, Touch screen, Encoder, Keyboard plate, Sensor, Probe, Cable etc.
3. Service Brands:
GE, , SPACELABS, SIEMENS, MINDRAY, NIHON KOHDEN, , TYCO, NONIN, TOSHIBA, MEDISON, BIOSOUND, HITACHI, HP, ATL, ALOKA etc.
|
- Agilent M1460A Sensor, Intellivue G5-M109A, Intellivue MX40,
- M1205A , M1001A, M1012A, M1034A, M3001A, M3012A,M3014A, M3015A,M3046A,
- MP2 X2,MP20,MP30, MP40, MP5, MP50 , MP60, MP70, MP80, MP90,
- V24E(M1204A), VM4, VM6, VM8,VS2+, VS3
|
GE |
- B20, B20i, B30, B40, B40i, B650, B850,
- DASH1800, DASH2000, DASH2500, DASH3000, DASH5000, Cardiocap 5,
- Datex-Ohmeda S3/S4/S5, GE DT-4500, Marquette EAGLE 4000,
- PRO1000, PRO300,
- SOLAR8000, SOLAR8000i, SOLAR8000M,
- V100, SAM Smart, SAM80
|
Nihon Kohden |
- BSM-2301A, BSM-2301K, BSM-2304A, BSM-2351A, BSM-2351C, BSM-4104A, BSM-5106A
- GF-210R, MU-631KA, WEP-4204K, WEP-4208A
|
Mindray |
- IMEC8, IMEC10, IMEC12,
- IPM8, IPM10, IPM12, IPM9800, MEC-1000, MEC-1200, MEC-200, MPM,
- PANORAMA, PM6000, PM1000, PM8000, PM8000E, PM9000, PM9000E,
- T1, T5, T6, T8, VS-800
|
Spacelabs |
- 90309, 90369, 90518,91369, 91370, 91387, 91388, 91393, 91496, 91518,
- elance93300,mCare300
|
Siemens |
- SC6002,SC6000,SC7000,SC6002 XL
|
Tyco |
|