Product Details:
|
|
Place of Origin: | Original |
---|---|
Brand Name: | GE |
Model Number: | 30344030 |
Payment & Shipping Terms:
|
|
Minimum Order Quantity: | 1 PCS |
Price: | Negotiation |
Packaging Details: | Normal Standard Package/ Individual Package |
Delivery Time: | 1-3 work days |
Payment Terms: | T/T, Western Union, Paypal |
Supply Ability: | 100 pcs per week |
Detail Information |
|||
Brand: | GE | Item: | Battery |
---|---|---|---|
PN: | 30344030 | Price: | Negotiate |
Payments: | Western Union, Paypal, T/T | Shipping: | DHL, UPS, ACS, EMS |
Delivery Time: | 1-3 Working Days | Stock: | Ex-stock |
Highlight: | medical battery,medical batteries |
Product Description
Original Medical Parts GE Defibrillator CARDIOSERV Battery Part Number 30344030 New
Company Business Scope
No. | PN | Use for GE monitor DASH3000/4000/5000/2500 ,SOLAR8000/8000M,GE S/5 AM/CAM,B20/30/40/450/650/1800 | Description |
1 | 2017003-001 | GE Original US Adult 5-lead Leadwire 3.6M #2017003-001 | CABLE ASSY ECG MLT-LNK 3/5 LEAD 3.6M AHA |
2 | 412681-001 | GE Original US 5-lead Leadwire 74CM/ 29 inches #412681-001 | LDWR AHA 5LD GRAB SH MOLDED |
3 | 411200-001 | GE Original US Adult Detachable Multi-Link Leadwire Set 5-lead 74CM/ 29 inches 74CM #411200-001 | Ldwr Set, Multi-Link Snap 29In AHA |
4 | 2006644-001 | GE Original SpO2 Leadwire 11 Needles Covidien Oxismart XL 2.9M #2006644-001 | Covidien Interface Cable |
5 | 2023211-001 | DASH2500 DASH1800 OXIMAX Can't use GE Original Covidien Oxismart XL 7 Needles Adult SpO2 Probe 1m #2023211-001 | Covidien Compatible Finger Sensor,with DB9 connector 1M |
6 | 2021406-001 | DASH2500 DASH1800 11 Needles GE Original SpO2 Leadwire Covidien OXIMAX 3M #2021406-001 | CABLE ASSY SPO2 Covidien OXIMAX 3M |
7 | DS100A | DASH2500 DASH1800 Covidien OXIMAX or Covidien Oxismart XL GE Original 7 Needles Adult SpO2 Probe #DS100A | DS1--A Covidien DuraSensor Reusable Finger Probe DS100A (1/box) |
8 | TS-F4-GE | GE B Series monitor,Ohmeda, 11 Needles GE OriginalAdult SpO2 Probe #TS-F4-GE | Ohmeda SPO2 Finger Sensor |
9 | 2017008-001 | GE Original Adult Blood Pressure Tube #2017008-001 | NIBP Dual Tube BP Tubing, Adult 3.6M for Dash and Tram |
10 | 2203 | GE Origianl Adult Cuff 23-33CM #2203 | DURA-CUF* Cuff, Adult, 2-Tube Sub-Min, Navy, |
11 | 30344030 | GE Original CARDIOSERV Defibrillator Battery 12V 1200mAh #30344030 | CARDIOSERV battery BTRY RECHGR NICD SCP |
12 | 21730403 | GE Original CARDIOSERV Defibrillator Paddles #21730403 | CARDIOSERV PADDLE PAIR DEFIB CSERV |
13 | 2029893-001 | GE Original MAC1200,MAC800 ECG Machine 10 Lead 14 Needles #2029893-001 | MAC1200 MAC800 Cable,Leadwire |
14 | 2037082-001 | GE Original MAC800 ECG Battery 7.2V 4500mAh 33Wh #2037082-001 | MAC800 battery |
15 | 2016560-002 | GE Original MAC5000 ECG Main Line 4.6m #2016560-002 | MAC5000 CABLE ASSY HOST CASE |
16 | 2016032-001 | GE Original CAM14 CAM Leadwire,Banana,10 Lead 90CM #2016032-001 | CAM 14 Leadwire Set, 10 Lead, Banana, AHA, Mixed Lengths |
17 | 2042686-002 | GE Original SEER Light7 EGC #2042686-002 #2008594-002 #2008596-001 | SEER Light patient cable 3 Channel |
18 | 5700HAX | GE Original CORO170 US 12 Needles #5700HAX | CORO170 U/S XDCR WATERTIGHT BUTTON 8' CABLE |
19 | 2264HAX | GE Original CORO170 Probe TOCO #2264HAX | CORO170 TOCO XDCR WATERTIGHT BUTTON 8' CABLE |
20 | 2003425-001 | GE Original Leadwire 10 Lead #2003425-001 | CABLE LEAD SET, ECG, 72 in. WIRES |
Details introduction
Repair and replace EGG, Defibrillator, Electrocardiogram Monitoring , Fetal Monitor Oximeter and parts. Detect and judge Circuit Board, Power Stripe/Panel, ECG PCB, SPO2 PCB, NIBP PCB, Display Screen , Touch Screen, Keyboard Plate, Parameter PCB, Rotary Knob etc. Sell and replace all kinds of Power Supply, ECG PCB, SPO2 PCB,NIBP PCB, Display Screen, Touch Screen , Keyboard Plate, Parameter PCB, Rotary Knob. Monitor/ Electrocardiograph for leasing, maintenance, guarantee repairing and replacing.
Common Faults Repair
1. Unbootable/ Unable to boot up 2. The module ( M3001A ) can’t detect blood pressure.
3. The module can’t be connected. 4. Automatically disconnect.
5. The sphygmomanometer has a leak. 6. NIBP equipment failure.
7. Unable to contact. 8. Error reporting MMS disconnected.
9. False alarm MMS pull out. 10. Can’t load out.
11. ECG malfunctions. 12. ECG equipment out of order.
13. Software upgrades. 14. NIBP fails to inflate.
15. IBP equipment faults. 16. M3012A module can’t be detected.
17. Automatically restart. 18. The encoder can’t work.
19. Blue screen appears after startup. 20. No ECG signal.
21. Unable to enter the select menu. 22. Alarm occurs when starting up, and the failure light is on.
23. Report CO2 plugging. 24. MMSL developing module faults.
25. M3015A / M3001A module faults. 26. No power display light.
27. NBP equipment faults. 28. ECG and oximeter equipment faults.
29. LCD lamp aging. 30. Inflated blood pressure does not indicate a number.
31. The key plate is out of order. 32. Encoder failure.
33. Can’t inflate. 34. NIBP equipment faults.
35. SP O2 and ECG equipment fault. 36. Unable to charge.
37. The touch screen can’t work. 38. The screen shows double image.
39. Error code 1000. Error code 20004. 40. No alarm sounds.
|
|
GE |
|
Nihon Kohden |
|
Mindray |
|
Spacelabs |
|
Siemens |
|
Tyco |
|
Notes from company
Enter Your Message